Your gate stops halfway. Or it ignores the remote. Or it sits there in silence while a car waits on the road behind you. A reset often fixes this. Turning the power off and on clears a glitch and lets the gate start fresh. But a reset only cures power and software faults. It won’t repair a worn motor, a bent hinge or a broken sensor.

In this guide
  1. 01What a reset means
  2. 02Reset or repair?
  3. 03Checks before you reset
  4. 04Step-by-step reset
  5. 05Opening the gate manually
  6. 06Remotes after a reset
  7. 07Mistakes to avoid
  8. 08Why it keeps needing a reset
  9. 09Why servicing matters
  10. 10When to call an engineer
  11. 11FAQs

This guide shows you the safe first reset, a simple test for swing gates with two motors, and the signs that it’s time to call an engineer. If your gate is stuck open or shut right now, our emergency gate repairs team can help.

Quick answer

To reset an automatic gate, switch off its power for one to two minutes, switch it back on, then press your remote once and wait. A working gate should open. If it won’t close, check the photocells. If it won’t open, test each motor on a two-motor swing gate. Always follow your gate’s manual.

IMPORTANT: ALWAYS FOLLOW THE MANUAL FOR YOUR SPECIFIC GATE SYSTEM.

Gate systems work in different ways. Brands such as Beninca, CAME, FAAC and Nice each use their own control boards, buttons and settings. This guide is general information only. It isn’t a substitute for your manufacturer’s instructions or a professional inspection. If you’re unsure at any point, stop and call an engineer.

Section 01What does it mean to reset an automatic gate?

Resetting an automatic gate means restarting its control board so it clears a fault and starts again. The safest and simplest way is a power reset. You switch the power off, wait, and switch it back on. It keeps your settings and your remotes.

Anything beyond a power reset depends on your system.

Type of resetWhat it doesCan you try it yourself?
Power resetRestarts the control board. Keeps your settings and remotes.Yes, if you follow the safety steps below.
Control board resetClears faults. May erase settings and remotes.Only if your manual explains it clearly. Otherwise, call an engineer.
Re-learning the open and close positionsTeaches the gate where to stop at each end.Only if your manual explains it clearly. Otherwise, call an engineer.

We don’t give step-by-step instructions for the last two on purpose. Every brand and model does them differently. Holding the wrong button, or holding it for too long, can wipe your settings or leave the gate running with the wrong limits.

Section 02Should you reset your gate or does it need a repair?

Reset your gate if it froze, lost power or shows a fault light with no sign of damage. Don’t reset it if you hear grinding, see damage or smell burning. A reset clears software glitches only. It can’t fix worn parts, and repeated resets on a damaged gate can make the damage worse.

Use this table to decide.

What you noticeLikely causeWill a reset help?
Gate froze after a power cut or stormControl board glitchYes. Try a power reset.
Gate ignores the remote but works from the keypadFlat remote battery or receiver faultMaybe. Change the remote battery first, and press once only.
Gate stops partway, then works next timeDirty photocell, obstruction or drifting limitsMaybe. Clean the sensors, then call us if it returns.
Gate won’t close and stays openBlocked, dirty or faulty photocellNo. Clear and clean the photocells first.
Gate reverses when closingDirty or misaligned photocellRarely. Clean and realign the sensors first.
One leaf of a swing gate won’t moveWiring or control board faultNo. Use the motor test below, or call us.
Grinding, squealing or clickingWorn gearbox, rollers or trackNo. It needs a repair.
Gate stops in cold or wet weather, then works laterMotor too weak for the gateNo. See the section on weak motors below.
Gate leans, drags or won’t latchSagging leaf or worn hingesNo. See our sagging gate repair page.
Gate was hit by a vehicleBent leaf, damaged post or trackNo. Stop using it.
Burning smell, or water in the control boxElectrical faultNo. Isolate the power and call an engineer.

Not sure which row matches your gate? Our guide to the most common electric gate problems explains each symptom in more detail.

Section 03What should you check before you reset your gate?

Spend five minutes on basic checks before you reset anything. Many gate faults come from simple causes: a tripped switch, something in the way, a dirty sensor or a manual release left unlocked. Checking first can save you a reset, and it makes the whole job safer.

  1. Check the power

    Is the gate’s isolator switch on? Has a breaker or RCD tripped at your consumer unit?

  2. Look for obstructions

    Leaves, gravel, snow, a bike or a bin can all stop a gate. Clear the path.

  3. Clean the photocells

    These are the small sensors on either side of the gateway. Wipe the lenses with a soft, dry cloth and check the light on each one. This is the first thing to check if your gate won’t close. If a photocell is blocked or not working, the gate will never close. It stays open.

  4. Test the remote

    Try the keypad or intercom too. If those work, the gate is fine and the remote is the problem.

  5. Check the manual release

    A gate left unlocked after a previous power cut won’t drive.

  6. Look at the control board

    Note any lights, beeps or codes. Take a clear photo of the board and its wiring before you touch anything.

That last step matters. If something goes wrong later, a photo shows an engineer exactly what you found.

Safety first

  • Keep children, pets and vehicles away from the gate while you work.
  • Never put your hand, arm or a tool in the path of a moving gate.
  • Never bypass or disconnect a photocell or safety edge to “get it moving”.
  • Switch off and isolate the mains before you open the control box or touch any wiring.
  • If you’re unsure at any step, stop and call an engineer.

Section 04How do you reset an automatic gate step by step?

Start with the power reset. If the gate still doesn’t open, and you have a swing gate with two motors, try the motor test. Stop as soon as the gate works, and stop at once if anything feels unsafe.

Step 1: Power reset

  1. Make sure nothing and nobody is in the gate’s path.

  2. Switch off the power at the gate’s isolator switch or fused spur. If you can’t find one, switch off the gate’s circuit at your consumer unit.

  3. Wait one to two minutes. This gives the control board time to clear.

  4. Switch the power back on.

  5. Give the board a moment to start up. You may see lights flash or hear a beep.

  6. Stand clear, with a good view of the gate. Press the remote once, then wait a few seconds. The gate takes a moment to respond.

After a power reset, the gate should respond and open. If it opens but then won’t close, a blocked or faulty photocell is the usual cause. Clean the lenses and clear the beam. If it moves normally, you’re done.

Some gates have a backup battery. If yours does, the board may stay on after the mains is off. Check your manual before you disconnect the battery.

Step 2: If the gate still doesn’t open, test each motor (swing gates with two motors)

Many swing gates have two arms, with a motor on each. A fault in one motor, or its wiring, can stop the whole gate. If one motor doesn’t move after the reset, the problem is usually the wiring or the control board. Testing the motors one at a time helps you confirm it.

Only do this if you’re comfortable opening the control box. If you’re not, call us.

  1. Switch off and isolate the power.

  2. Open the control box. Photograph the wiring so you can put everything back exactly as it was.

  3. Disconnect one motor. Keep its wires apart and clear of metal.

  4. Switch the power back on and press the remote. Stand well clear. The other motor should move its leaf.

  5. Switch the power off again. Reconnect the first motor, then disconnect the second one.

  6. Switch the power on and press the remote again. Now the first motor should move.

Here’s how to read the result.

What happensWhat it likely means
One motor works alone, the other doesn’tA wiring or control board problem is the likely cause. An engineer can find which.
Both motors work alone, but not togetherThere may be a wiring or settings problem. Call an engineer.
Neither motor works, even on its ownThe control board may be damaged.

A damaged control board usually can’t be repaired, so replacement is the usual fix. That’s a job for an engineer, and the right board depends on your system.

Single-motor gates, such as most sliding gates, can’t use this test. If a power reset doesn’t work, check the basics above and call us.

Step 3: Control board resets and learning the gate’s positions

This is where we stop. Resetting a control board, or teaching the gate its open and close positions, depends entirely on your system. A button that does one thing on a CAME board can do something different on a FAAC or Nice board.

IMPORTANT: DON’T GUESS. FOLLOW YOUR MANUAL, OR CALL AN ENGINEER.

If you have the manual, follow it exactly, step by step. If you don’t, find the make and model on the label on the motor or control box. Then look for the manual on the manufacturer’s website.

A word on low-cost kits. Cheap imported gate systems often come with a manual that is unclear, badly translated or missing. If you can’t find clear instructions for your gate, don’t experiment with the control board. Call an engineer.

Section 05How do you open an automatic gate manually?

Use the manual release. It’s a built-in emergency feature, so you don’t need to switch the power off to use it. Unlock the release with its key, move the gate by hand, and relock the release when you’re done.

  1. Find the release on the motor housing. It’s often behind a small cover and may need a key. Your manual shows exactly where.

  2. Unlock it with the release key. The gate should now move freely.

  3. Push the gate slowly. Gates are heavy, and a sliding gate can roll away on a slope. Ask someone to help with larger gates.

  4. Relock the release when you finish. Until you do, the motor can’t move the gate.

Switching the power off first is optional. Some manuals recommend it, so check yours. But don’t worry if you don’t know how to do it. The release is made for emergencies such as a power cut, when you need the gate open quickly.

Keep the release key somewhere easy to find, such as on a hook inside the house. You don’t want to hunt for it during a power cut.

Section 06What about remotes after a reset?

A power reset keeps your remotes. Pairing a new remote, or re-pairing after a board reset, depends on your receiver, and the steps differ between brands. Follow your manual for this too.

If your remote stops working, change its battery first. A broken remote can’t be repaired. If the battery doesn’t help, or you’ve lost one, you’ll need a replacement, and it must be paired to your gate. Call us and we can help.

Section 07What mistakes should you avoid with an automatic gate?

The most common mistake is pressing the remote too fast. Other big ones are resetting again and again, guessing at control board settings and bypassing sensors to keep the gate moving. These can hide a real fault and put people at risk. If a reset doesn’t hold, treat that as a warning, not a nuisance.

  • Pressing the remote again and again. A gate takes a few seconds to react. Press the button once and wait. Rapid presses can stop the receiver reading the signal. On some gates, a second press also stops or reverses the gate.
  • Resetting on repeat. If you need a reset every week, something underneath is failing.
  • Guessing at the control board. Pressing buttons without the manual can wipe settings and leave the gate unsafe.
  • Leaving the manual release unlocked. The gate won’t drive, and you may think the reset failed.
  • Disconnecting safety devices. Photocells and safety edges stop the gate from trapping people.
  • Working with the power on. Always isolate the mains before you touch wiring.

Section 08Why does an automatic gate keep needing a reset?

A gate that needs regular resets has an underlying fault. Common causes include an unstable power supply, a tired backup battery, dirty or misaligned photocells, worn parts, water in the control box, drifting limit settings and a motor that is too weak for the gate. A reset hides the symptom. A service finds the cause.

Likely causeWhat you may noticeWhat fixes it
Power supply or backup batteryGate dies after power cuts, or runs slowlyTest the supply and replace a worn battery
PhotocellsGate stops or reverses at the same spotClean, realign or replace the sensors
Worn motor, gearbox or rollersNoise, slow movement, stallingRepair or replace the worn part
Water or pests in the control boxRandom faults after rain, chewed cablesDry, clean and reseal the box, then replace damaged parts
Motor too weak for the gateGate stops or struggles in cold or wet weather, then works laterA stronger motor, rated well above the gate’s weight
Drifting limitsGate stops short or hits the end stopsAn engineer resets the limits and checks for wear
Ageing control boardErrors with no clear causeReplace the board

Can a weak motor make a gate stop in cold or wet weather?

Yes. Some installers fit a motor that only just copes with the gate’s weight. For example, a 300 kg gate on a system rated for 300 kg. Cold or wet weather puts extra strain on that motor. With no spare power, it can give up for a while, then work again when conditions improve.

We choose a system rated well above the gate’s weight. For example, for a 300 kg gate we would use a system rated for 700 kg. The extra power means the motor doesn’t struggle. A reset won’t fix a weak motor. If this sounds like your gate, an engineer can check the motor’s rating against the gate’s weight.

Motor faults are the ones people put off the longest. Our gate motor repairs page explains what we fix, and our guide on whether to repair or replace a gate motor helps you decide.

For wider faults, see our electric gate repairs service. And a regular gate service catches most of these problems before they leave you stuck.

One small habit helps. Stick a label inside the control box with your gate’s make, model and the date of the last service. Next time, you’ll have the details ready, and so will we.

Section 09Why does regular servicing matter for gate safety?

A serviced gate is less likely to need a reset, and it’s safer to use. A regular service lets an engineer check the parts that protect people, such as photocells, safety edges and force settings. It also lets them spot wear before it becomes a fault. That means fewer resets for you, and less to worry about.

Safety matters because automatic gates are heavy and move with real force. In 2010, the Health and Safety Executive for Northern Ireland issued an alert after a young child was trapped by an electrically powered sliding gate. Its investigation found no planned maintenance system, and the gate kept running with two protective safety devices defective (HSENI, 2010).

The Property Institute’s advice note on powered gates adds that the HSE treats residential automatic gates as high risk where children may be nearby. It recommends a company that tests closing forces with measuring equipment and keeps a maintenance log.

A reset is a handy first step. A service is what keeps the gate working properly. If you’d rather have an engineer look at it before something goes wrong, book a gate service.

Section 10When should you call a gate engineer?

Call an engineer if a power reset doesn’t fix the problem, the gate is stuck open or shut, you can see damage or the same fault keeps coming back. Call too if neither motor works on its own, you can’t find your manual or you don’t feel confident. A safe gate is worth more than a DIY fix.

Call us if:

  • The gate is stuck open or shut and you can’t secure your property.
  • You hear grinding, squealing or clicking from the motor.
  • The gate has been hit, or the leaf, post or track looks bent.
  • Neither motor moves its leaf, even when tested on its own.
  • The gate stays open, and cleaning the photocells doesn’t help.
  • The gate stops in cold or wet weather, which can mean the motor is too weak for it.
  • Lights or beeps point to a fault that won’t clear.
  • You need a control board reset, but your manual is unclear or missing.
  • The gate hasn’t had a safety check in a long time.

If your gate is stuck right now, go straight to our emergency gate repairs page. We repair electric, automatic and manual gates across London and the Home Counties.

Not sure we cover your area? Pick the page that matches where you are:

Tell us what your gate is doing, and we’ll tell you how we can sort it. Contact Gate Fixers or call 0785 104 6581.

Section 11Frequently asked questions

How long should I leave the power off when resetting an automatic gate?

Leave it off for one to two minutes. This gives the control board time to clear the fault from its memory. If your gate has a backup battery, the board may stay powered. Check your manual before you disconnect the battery.

What should I do if my gate doesn’t open after I turn the power off and on?

First check for obstructions, a tripped switch and an unlocked manual release. On a swing gate with two motors, test each motor on its own with the power isolated. If neither moves, the control board may be damaged. Call an engineer.

Will resetting my gate delete my remotes?

A simple power reset keeps your remotes. A control board reset may wipe them, depending on the make. Follow your manual before you hold any reset or learn button. Keep every remote nearby so you can re-pair them if needed.

Can I reset my gate if I don’t have the manual?

You can do a power reset without it. For anything beyond that, find the make and model on the label on the motor or control box, then look for the manual online. Low-cost imported kits often have unclear manuals. If you can’t find clear instructions, call an engineer.

Why doesn’t my gate respond when I press the remote quickly?

A gate needs a few seconds to read the signal and start moving. Pressing the button again and again can stop the receiver picking up the signal. On some gates, a second press stops or reverses the gate. Press once, then wait a few seconds.

Why won’t my gate close and stays open?

If a photocell is blocked, dirty, misaligned or not working, the gate will never close. It stays open. Clear anything in the beam, wipe both lenses and check the light on each unit. If it still won’t close, call an engineer.

Why does my gate stop working in cold or wet weather?

Cold and wet weather make a gate harder to move. If the motor is only just strong enough for the gate’s weight, it can give up until conditions improve. A motor rated well above the gate’s weight avoids this. A reset won’t fix it, so ask an engineer to check the motor.

Wrapping upThe short version

Turn the power off, wait a minute or two, then turn it back on. Press the remote once and wait a few seconds. If the gate won’t close, check the photocells. If it won’t open, test each motor on a two-arm swing gate. Beyond that, the right steps depend on your system, so follow your manual or call an engineer.

If the fault returns, your gate is telling you something. Don’t keep resetting it. Get it looked at.